There are
different way of measuring the capacitance, the circuit
described here can measure the capacitance and display in 7
segment display. Wide range of capacitance pico to micro Farad
can be measured by the system. Range of capacitance is selected
using combination of the selector switches SW1 and SW2
(combination chart can be seen on circuit diagram).
The principle of
operation is counting the pulse number derived from a constant
frequency oscillator during a fixed time interval produced by
another lower frequency oscillator. The oscillator uses the
capacitor being measured as the timing. The capacitance
measurement is proportional during pulse counting during a fixed
time interval. The astable oscillator formed by IC1c produces a
pulse train of constant frequency. Gate IC1a also forms an
oscillator whose oscillation period is given approximately by
the equation: T=0.7RC
Period T is
linearly dependent on the capacitance C. this period is used as
the time interval for on measurement. The differentiator network
following the oscillator creates the negative spikes shaped in
narrow pulses by IC1b NAND Schmitt trigger. The differentiator
formed by R1 and C1 produces a negative spike which resets
the-counters. The display shows the number of high frequency
oscillator pulses entering the counter during the measurement
period.
Schematic
|